Scale parameters and functions
8.5 DR 4 Output of calculated calibration digits
SIWAREX WP321
58 Manual, 07/2014, A5E33715669A-02
DR 4 Output of calculated calibration digits
Date record DR 4 outputs the digits calculated from automatic scale calibration.
This data record cannot be sent to the scale.
Table 8- 2 Assignment of data record 4
Data record num-
ber
Contains no. of data
record
USHORT 2 r 4 - -
Length Data record length
information
USHORT 2 r 28 - -
Application Information about
which application the
DR belongs to
USHORT 2 r 201 - -
Version identifier Information on the
current data record
version
USHORT 2 r 1 1 65 635
Calibration digits
0, 1, 2 (calculated)
(Page 58)
Calibration digits 0
(calculated): Calibra-
tion digits calculated
in "Automatic Cali-
bration"
LONG 4 r ?
Calibration digits 1
(calculated): Calibra-
tion digits calculated
in "Automatic Cali-
bration"
LONG 4 r 0
Calibration digits 2
(calculated): Calibra-
tion digits calculated
in "Automatic Cali-
bration"
LONG 4 r 0
Reserve 1 Reserve SHORT 2 r 0 - -
Reserve 2 Reserve USHORT 2 r 0 - -
Reserve 3 Reserve FLOAT 4 r 0 - -
Calibration digits 0, 1, 2 (calculated)
The calculation is based on the parameters from DR 3 and DR 10 identified by bold font and
is activated by the command no. 82.