Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-33
OUTPut[1|2]:POLarity
This command inverts a specified output waveform relative to the offset level. The
query command returns the polarity for the specified channel.
Group
Output
Syntax
OUTPut[1|2]:POLarity{NORMal|INVerted}
OUTPut[1|2]:POLarity?
Arguments
NORMal sets the specified output waveform polarity to Normal.
INVerted sets the specified output waveform polarity to Inverted.
Returns
NORM|INV
Examples
OUTPut1:POLarity NORMal
sets the CH 1 waveform polarity to Normal.
OUTPut[1|2][:STATe]
This command sets or query whether to enable the arbitrary/function generator
output for the specified channel.
Group
Output
Syntax
OUTPut[1|2][:STATe] {ON|OFF|<NR1>}
OUTPut[1|2][:STATe]?
Arguments
ON or <NR1>0 enables the arbitrary/function generator output.
OFF or <NR1>=0 disables the arbitrary/function generator output.
Returns
<NR1>
Examples
OUTPut1:STATe ON
sets the arbitrary/function generator CH 1 output to ON.

Table of Contents

Other manuals for Tektronix AFG3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix AFG3000 Series and is the answer not in the manual?

Tektronix AFG3000 Series Specifications

General IconGeneral
BrandTektronix
ModelAFG3000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals