Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-95
SYSTem:ERRor[:NEXT]?
This query-only command returns the contents of the Error/Event queue.
Group
System
Syntax
SYSTem:ERRor[:NEXT]?
Arguments
None
Returns
<Error/event number>::=<NR1>
<Error/event description>::=<string>
Examples
SYSTem:ERRor:NEXT?
might return the following response:
–410,”Query INTERRUPTED”
If the instrument detects an error or an event occurs, the event number and event
message will be returned.
SYSTem:KCLick[:STATe]
This command enables or disables the click sound when you push the front panel
buttons or turn the general purpose knob. The query command returns “0” (OFF)
or “1” (ON).
Group
System
Syntax
SYSTem:KCLick[:STATe] {ON|OFF|<NR1>}
SYSTem:KCLick[:STATe]?
Arguments
ON or <NR1>0 enables click sound.
OFF or <NR1>=0 disables click sound.
Returns
<NR1>
Examples
SYSTem:KCLick:STATe ON
enables the click sound.

Table of Contents

Other manuals for Tektronix AFG3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix AFG3000 Series and is the answer not in the manual?

Tektronix AFG3000 Series Specifications

General IconGeneral
BrandTektronix
ModelAFG3000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals