Multi Pro 1750
Page 5 − 16
Electrical System
Service Screens
The service screen (Fig. 19) contains machine opera-
tional information including Faults and Hours. If the cor-
rect personal identification number (PIN) has been
entered (see Settings Screen − Protected Menus in this
chapter) the service screen allows viewing the Flow
Rate, Flow Calibration Value and Speed Calibration Val-
ue. To scroll through the list of service items and view the
current values, press the center/down button (as indi-
cated by the
at the bottom of the screen).
Faults: The Faults screen (Fig. 18) will list the last time
faults were cleared and all machine electrical faults that
have occurred since the faults were last cleared from the
InfoCenter. The faults will be identified by fault number
and when the fault occurred. Fault Codes that might oc-
cur on the machine are listed in the Troubleshooting
section of this chapter. If the correct personal identifica-
tion number (PIN) has been entered (see Settings
Screen − Protected Menus in this chapter) the service
screen allows access to additional information about
each fault present and provides the ability to clear any
of the present faults.
Hours: The Hours screen (Fig. 19) will list the following:
S Key On − Identifies the number of hours that the
ignition switch has been in the RUN position.
S Machine Run − Identifies the number of hours
that the engine has been running.
S Engine Service − Identifies the number of hours
remaining before the next recommended service.
If the correct personal identification number (PIN) has
been entered (see Settings Screen − Protected Menus
in this chapter) the service screen allows access to reset
the engine service timer.
Flow Rate: Displays the current flow rate. The rate dis-
played here should be consistent with catch test results
after flow calibration. If not, flow meter and/or flow meter
sensor may not be functioning correctly.
Flow Calibration: Displays the current multiplier used
to calculate the difference between the assumed flow
and the calibrated flow. The assumed flow multiplier is
1.00. The calibrated flow multiplier can be equal to, high-
er or lower than the assumed flow.
Speed Calibration: Displays the current multiplier used
to calculate the difference between the assumed speed
and the calibrated speed. The assumed speed multiplier
is 1.00. The calibrated speed multiplier can be equal to,
higher or lower than the assumed speed.
To return to the previous screen, press the Menu/Back
button (as indicated by the
at the bottom of the
screen).
1. Service items
2. Left/back button
3. Center/down button
4. Right/forward button
Figure 17
Service
Faults:
Hours:
1
2
3
4
1. Fault items
2. Left/back button
3. Center/down button
Figure 18
Faults
Cleared @
4.29 Ago
1
# 4: 0.28 Ago
# 16: 1.40 Ago
2
3
1. Hours items
2. Left/back button
3. Center/down button
Figure 19
Hours
On:
Machine Run:
Service:
92.5 Hours
88.4 Hours
63.7 Hours
1
2
3

Table of Contents

Other manuals for Toro Multi Pro 1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Multi Pro 1750 and is the answer not in the manual?

Toro Multi Pro 1750 Specifications

General IconGeneral
BrandToro
ModelMulti Pro 1750
CategoryPaint Sprayer
LanguageEnglish

Related product manuals