Maintenance
Drive unit - diesel engine
BA RD24_RD28 en us 06
105
Lubricating oil change
intervals
These intervals depend, e.g., on:
■
Lubricating oil quality
■
Fuel sulphur content
■
The mode in which the diesel engine is used
Change lubricating oil after half the interval indicated, e.g., when at least
one of the following conditions is true:
■
Continuous ambient temperature below –10 °C (14 °F) or lubricating
oil temperature below 60 °C (84 °F).
■
Operation using biodiesel fuel
NOTE
Maintenance work must be carried out at least once a year.
This applies, in particular, when the operating hours indicated
in the maintenance intervals are not reached within a year.
4.02.02 Maintenance points at the Diesel engine when changing oil
NOTE
For engine maintenance see instruction manual for diesel
engine!
[A] Oil gauge stick [B] Oil filler
[C] Oil drain screw
NOTE
Lubricant only admissible if containing this marking (see
page 128 sqq.).