Operation
Stopping, switching off engine, leaving machine
80
BA RD24_RD28 en us 06
3.05 Stopping, switching off engine, leaving machine
WARNING
Uncontrolled driving behaviour!
Autonomous movement of the machine can lead to serious injuries or
death.
■
Switch off diesel engine even if you leave the operator platform
only for short time.
002-22
Stopping
17256
310
304
504
312 501
503501 501
1. Vibration / Oscillation [503] — OFF
2. Drive lever [501] — CENTRE
The hydrostatic drive brings the machine to a stop.
Before switching off the
Diesel engine
1. Vibration / oscillation [312] — OFF
2. Parking brake [304] — APPLIED
3. Engine speed [504] — MIN
4. Fully lower attached accessory equipment.
Shut down the diesel engine Do not switch off engine directly after full load operation. Instead, let
it run for 1-2 minutes with idling speed for temperature compensation
purposes.
1. Key [310] — I → 0
NOTE
The battery discharges rapidly if the engine is at a standstill
and the electrical system is switched on (switch [310] in
position I).
000-02
Leaving the machine The driver may only leave the machine when orderly parked. Traffic
regulations have to be observed as well.