1-5
Phaser 3635MFP
SCP 4, SCP 5
Service Call Procedures
Draft 4
Machine Settings
To make any adjustments to the machine, refer to ADJ 1.1 Machine Settings.
Additional Information
If necessary, refer to the following general procedures and information:
• GP 1 Diagnostics Entry
• GP 2 Fault Codes and History Files
• GP 3 Machine Status
• GP 4 System Administration Tools
• GP 5 Reports
• GP 6 Firmware Upgrade
• GP 7 Machine Specifications
• GP 8 DADF Document Feeding Specifications
• GP 9 Paper and Media Specifications
• GP 10 General Disassembly Precautions
• GP 11 Service Information
• GP 12 User Interface Tests Description
• GP 13 Installation Space Requirements
• GP 14 Glossary of Terms, Acronyms and Abbreviations
• GP 15 Shading Test
• GP 16 High Frequency Service Items
• GP 17 Restriction of Hazardous Substances (RoHS)
• GP 18 Scan Edge Print
SCP 5 Subsystem Maintenance
Subsystem Maintenance contains information regarding the component life of the machine.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
• Component Life
•HFSI
Component Life
The design life of the major components are shown in Table 1. Environmental conditions and
actual use will vary these factors. The component life shown in Table 1 is for reference only.
Table 1 Component life expectancies
Part Component life Parts list reference
DADF retard pad assembly 50k feeds PL 5.30 Item 2
DADF pickup assembly 80k feeds PL 5.25 Item 2
Tray 1 pickup roll 150k feeds PL 10.22 Item 14
Tray 2 pickup roll 150k feeds PL 8.17 Item 31
Transfer roll 100k prints PL 9.10 Item 2
Fuser assembly 100k prints PL 10.10 Item 1
Starter print cartridge
Print cartridge
5K prints
10K prints
PL 9.10 Item 1