Note:
(1) The power supply voltage range of P-/P+24 V and D-/D+ 24 V is 18V ~ 25V. The supply voltage range of P-/
P+ 5V and D-/D+ 5V is 3.3V ~ 5V. If it is lower than 18V/3.3V, there may be abnormal pulse and direction.
(2) In order to enhance the anti-interference, it is recommended to use twisted pair shielded wire.
(3) The servo pulse input port is on at 10mA.
(4) If the controller is Xinje PLC and the rated current of pulse output port is 50mA, according to this data, it can
be judged that theoretically one pulse can drive five servos at most. It is recommended that the maximum number
should not be more than 3.
3.2.2 SI input signal (without brake)
Please use a relay or an open collector transistor circuit to connect. When using relay connection, please select the
relay for small current. If the relay is not small current, it will cause bad contact.
Defaulted assignment of input terminals