136
Alarm
code type
Alarm
code
Explanation
Property
Servo
status
when
alarming
Historical
records
Can be
cleared
Whether
power on is
needed to
clear the
alarm
31
0
E-310
Motor power mismatch
Yes
Servo off
1
E-311
Motor code missing
Yes
Servo off
2
E-312
Reading motor parameter is
damaged
Yes
Servo off
3
E-313
Encoder software version
mismatch
Yes
Servo off
4
E-314
Encoder software version
not supported
Yes
Servo off
5
E-315
Unable to read valid motor
parameters
Yes
Servo off
6
E-316
Reading motor code is
inconsistent with setting
code
Yes
Servo off
85
2
E-852
Interruption of data
interaction with CANopen
master station
No
Servo off
6.2 Analysis of alarm types
DF3E alarm code format is E-XX□, “XX” means main type, “□” means sub-type.
Main
type
Sub
type
Code
Description
Reasons
Solutions
01
0
E-010
Firmware
version
mismatch
Downloaded
firmware version
error
Please contact the agent or the
manufacturer
3
E-013
FPGA loading
error
program damaged
device damaged
Please contact the agent or the
manufacturer
4
E-014
FPGA Access
error
(1) Program damage
(2) Device damage
(3) serious external
interference
Please contact the agent or the
manufacturer
5
E-015
Program running
error
Program damage
Please contact the agent or the
manufacturer
6
E-016
Hardware error
program damaged
hardware damaged
Excessive intensity
of external
interference
Check the input voltage,
whether the input phase is missing
or the supply voltage is too low
Contact agent or manufacturer
7
E-017
Processor
Running
Timeout
Program damage
Please contact the agent or the
manufacturer
9
E-019
System password
error
Program damage
Please contact the agent or the
manufacturer
02
0
E-020
Parameter
loading error
Failure of parameter
self-checking
Re-energizing can restore default
parameters, if there are repeated
problems, please contact the agent
or manufacturer.
1
E-021
Parameter range
beyond limit
Setting values are not
within the prescribed
range
Check parameters and reset them

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DF3E Series and is the answer not in the manual?

Xinje DF3E Series Specifications

General IconGeneral
BrandXinje
ModelDF3E Series
CategoryServo Drives
LanguageEnglish

Related product manuals