EasyManuals Logo
Home>Zebra>Barcode Reader>DS6878

Zebra DS6878 Product Reference Guide

Zebra DS6878
528 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
4 - 26 DS6878 Product Reference Guide
Connection Maintenance Interval
When a digital scanner disconnects from a cradle due to a Link Supervision Timeout, the digital scanner
immediately attempts to reconnect to the cradle for 30 seconds. If the auto-reconnect process fails, it can be
restarted by pulling the digital scanner trigger.
To guarantee that a disconnected digital scanner can reconnect when it comes back in range, the cradle
reserves the connection for that digital scanner for a period of time defined by the Connection Maintenance
Interval. If the cradle is supporting the maximum three digital scanners and one digital scanner disconnects, a
fourth digital scanner cannot pair to the cradle during this interval. To connect another digital scanner: either
wait until the connection maintenance interval expires then scan the PAIR bar code on the cradle with the new
digital scanner; or, scan Lock Override ( page 4-23) with the new digital scanner then scan the PAIR bar code
on the cradle.
Connection Maintenance Interval options are:
15 minutes
30 minutes
One hour
Two hours
Four hours
Eight hours
24 hours
Indefinitely.
Considerations
The system administrator determines the Connection Maintenance Interval. A shorter interval allows new
users to gain access to abandoned connections more quickly, but causes problems if users leave the work
area for extended periods. A longer interval allows existing users to leave the work area for longer periods of
time, but ties up the system for new users.
To avoid this conflict, users who are going off-shift can scan the unpair bar code on page 4-24 to ignore the
Connection Maintenance Interval and make the connection immediately available.
NOTE The Connection Maintenance Interval only applies in locked pairing mode (see page 4-23).
NOTE When the CR0078-S cradle supports the maximum three digital scanners and the CR0078-P supports the
maximum seven digital scanners, it stores the remote pairing address of each digital scanner in memory
regardless of the digital scanner condition (e.g., discharged battery). When you want to change the digital
scanners paired to the cradle, unpair each digital scanner currently connected to the cradle by scanning
the Unpairing bar code prior and reconnect each appropriate digital scanner by scanning the PAIR bar
code on the cradle.

Table of Contents

Other manuals for Zebra DS6878

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS6878 and is the answer not in the manual?

Zebra DS6878 Specifications

General IconGeneral
Wavelength655 nm
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standards1D, 2D, PDF417, PDF417, microPDF417, Composite Codes (CC-A, CC-B, CC-C), U.S. Postnet and Planet, U.K., Japan, Australian, Netherlands KIX code, Royal Mail 4 State Customer, UPU ICS 4 State Postal, USPS 4CB, TL C-39, Aztec (Standard, Inverse), MaxiCode, DataMatrix/ECC 200 (Standard, Inverse), QR Code (Standard, Inverse and Micro)
Tilt reading angle-360 - 360 °
Input voltage5 V
BluetoothYes
Dimensions (WxDxH)69 x 97 x 185 mm
CertificationFCC, RoHS
Product colorBlack
International Protection (IP) codeIP43
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Cables includedUSB
Weight and Dimensions IconWeight and Dimensions
Weight238 g

Related product manuals