Output Frequency
As shown below, the output frequency range depends on the function
currently selected. The default frequency is 1 kHz for all functions.
For arbitrary waveforms that you create and download to memory,
the maximum frequency depends on the number of points specified in
the waveform. As shown below, the maximum output frequency
decreases as you specify more points in the waveform. The five built-in
arbitrary waveforms can be output at a maximum of 5 MHz.
Function
Sine
Square
Triangle
Ramp
Built-In Arbs
1
Minimum Frequency
100
m
Hz
100
m
Hz
100
m
Hz
100
m
Hz
100
m
Hz
Maximum Frequency
15 MHz
15 MHz
100 kHz
100 kHz
5 MHz
1 There are five built-in arbitrary waveforms stored in non-volatile memory:
sinc, negative ramp, exponential rise, exponential fall, and cardiac.
Number of Arb Points
8 to 8,192 (8k)
8,193 to 12,287 (12k)
12,288 to 16,000
Minimum Frequency
100
m
Hz
100
m
Hz
100
m
Hz
Maximum Frequency
5 MHz
2.5 MHz
200 kHz
3
Chapter 3 Features and Functions
Output Configuration
57

Table of Contents

Other manuals for Agilent Technologies 33120A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33120A and is the answer not in the manual?

Agilent Technologies 33120A Specifications

General IconGeneral
BrandAgilent Technologies
Model33120A
CategoryInverter
LanguageEnglish

Related product manuals