38 Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
Chapter 3 Configurable Functions
Table 7 - Recommended Multiple Sampling
Stand-by Mode
If, in mobile applications, vehicles are not moved for a time (for example, for
battery charging), the OSSDs can be switched to the OFF state and the laser
on the SafeZone Mini device can be switched off. In this way, the power
consumption of the device is reduced.
In this way, you also help prevent the safety laser scanners from optically
interfering with each other and entering an error condition.
The function can be realized with the aid of the stand-by mode.
To switch to the stand-by mode, one universal I/O connection must be
configured as standby input on the SafeZone Mini device. (see Universal I/O
Connections on page 28).
Application Recommended Multiple Sampling
Stationary under clean ambient conditions 2 times
Vertical applications 2 times
Mobile 4 times
Stationary under dusty ambient conditions 8 times
TIP With multiple sampling, you can increase the availability of a system.
You can configure the multiple sampling in the SCD software. You can set individual multiple sampling
for each monitoring case.
IMPORTANT The stand-by mode does not occupy a monitoring case.