7-10 Application Specific Instructions
Use SQC
When the status of all non-masked bits in the source word match those of the
corresponding reference word, the instruction sets the found bit (FD) in the
control word. Otherwise, the found bit (FD) is cleared.
The bits mask data when reset and pass data when set. The instruction will not
change the value in the destination word unless you set the mask bits. The
mask can be fixed or variable. If you enter a hexadecimal code, it is fixed. If
you enter an element address or a file address for changing the mask with each
step, it is variable.
When the rung goes from false-to-true, the instruction increments to the next
step (word) in the sequencer file. Data stored there is transferred through a
mask and compared against the source data for equality. If the source data
equals the reference data, the FD bit is set in the SQC’s control counter.
Current data is compared against the source every scan that the rung evaluates
as true.

Table of Contents

Other manuals for Allen-Bradley SLC 500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley SLC 500 Series and is the answer not in the manual?

Allen-Bradley SLC 500 Series Specifications

General IconGeneral
Programming SoftwareRSLogix 500
SeriesSLC 500
CategoryController
ManufacturerAllen-Bradley (Rockwell Automation)
I/O CapacityUp to 4096 I/O points
Communication PortsDH-485
Programming LanguagesLadder Logic
Operating Temperature0 to 60 °C (32 to 140 °F)
Relative Humidity5% to 95% (non-condensing)
Memory4K to 64K words (depending on the processor)
Power SupplyAC or DC (depending on the module)

Related product manuals