1508685 Rev D CHP Max Element Management Modules CHP-CMM, CMM-1, SMM, and SMM-1 6-11
To install the CMM or SMM
1. The CMM Address is located on a separate “CMM Address” label located just below
the serial number label on all CMMs/SMMs manufactured after July 1, 2005. Only a
Serial Number label is placed on CMMs and SMMs manufactured before July 1, 2005.
Modules manufactured before July 1, 2005 use the last five digits of the Serial
Number as the “CMM Address”. The SMM uses this address to poll the shelf and
modules in the shelf. The CMM Address has a range of 1 to 65534. Refer to Figure 6.5
for the location of the serial number and CMM address label (on or after 7-1-2005)
on the CMM or SMM. Make note of the CMM Address before installing the CMM or
SMM module.
2. Gently insert the CMM or SMM into the slot just to the left of the power supply
module(s). Be careful to align the circuit card of the module with the metal guides
on the top and bottom of the chassis.
3. Carefully slide the CMM or SMM into the chassis until it is fully seated in the
backplane. The latch on the front panel locks when the module is fully seated.
Figure 6.5
Serial Number/CMM
Address Label
Location on CMM
and SMM
Each SMM is shipped with the following default IP configuration information. This
information is needed to access the SMM in order to change the IP address, netmask, and
gateway information. Refer to Configuring CMM, CMM-1, SMM, or SMM-1 to change this
information.
Note CMMs/SMMs manufactured after July 1, 2005 have a five digit CMM address
label. This address should be used instead of the last five digits of the serial number.
Address Type Default Address
IP address 192.168.1.1
netmask 255.255.255.0
gateway 192.168.1.1
Serial Number Label Location
(use last 5 digits of the serial number as the CMM
Address for modules manufactured before
CMM Address Label Location
(use CMM Address for modules manufactured on
or after 7-1-2005)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals