6-10 CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies 1508685 Rev D
Installation of CHP Max Craft Management Software
To install the CHP Max Craft Management Software refer to Installing CHP Max Craft
Management Softwarepage 1-11
CHP Max System Management Module
CHP Max System Management Module (SMM) remotely monitors and controls application
modules installed in the same chassis and the application modules installed in up to nine
additional chassis. The SMM is an SNMP Agent that can communicate with SNMP Managers
typically located in the Network Operating Center (NOC). The SMM provides the following
features:
Communicates with CMM via RS-485 daisy chain
Communicates with SNMP Manager in NOC via Ethernet
Supports all SNMP functions and HMS functions including downloads and trap
handling
Supports all released indoor plant equipment MIBs (can be downloaded from
www.scte.org)
ANSI/SCTE 36 2002R2007 SCTE-ROOT
ANSI/SCTE 37 2010 SCTE-HMS-ROOTS
ANSI/SCTE 38-1 2009 SCTE-HMS-PROPERTY
ANSI/SCTE 38-8 2009 SCTE-HMS-DOWNLOAD
ANSI/SCTE 38-11 2008 SCTE-HMS-HEADENDIDENT-MIB
ANSI/SCTE 83-1 2006 SCTE-HMS-HE-OPTICS-MIB
ANSI/SCTE 83-4 2009 SCTE-HMS-HE-RF-MIB
ANSI/SCTE 84-1 2009 SCTE-HMS-HE-COMMON-MIB
ANSI/SCTE 84-2 2009 SCTE-HMS-HE-POWER-SUPPLY-MIB
ANSI/SCTE 84-3 2009 SCTE-HMS-HE-FAN-MIB
ANSI/SCTE 85-1 2009 SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB
ANSI/SCTE 85-2 2009 SCTE-HMS-HE-OPTICAL-RECEIVER-MIB
ANSI/SCTE 85-3 2009 SCTE-HMS-HE-OPTICAL-AMPLIFIER-MIB
ANSI/SCTE 94-1 2009 SCTE-HMS-HE-RF-AMP-MIB
Supports ARRIS proprietary MIBs
SNMP v2/v3 compatible and complies with IETF and SCTE-HMS standards
Installation/Replacement of the CMM or SMM
CAUTION The SMM must be installed into a chassis with a label containing
CHP-CHASSIS-19 on the right front flange of the chassis. If label is not located on the
front right flange, do
NOT install the SMM into the chassis. Installation of the SMM
into a chassis without a label on the right front flange (label with 961015726201 on
right side) will damage the SMM and void the warranty.
Note Ensure that the desired Power Supply configuration is installed before
installing the SMM.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals