Rev D CHP Max5000 Chassis (Rear Fiber Version) 2-3
Metal guides on the inside of the chassis align with the plastic guide rail on top of the
modules, allowing the modules to slide into the chassis easily. All RF and optical connections
are made directly to the application modules installed in the chassis. Modules plug into the
backplane interconnection circuit board (with DC bus and SPI bus), which routes DC voltages
and communications signals between modules.
Each chassis requires only one power supply and accepts a second for load sharing and
redundancy. A management module provides an interface between the management system
and the CHP Max5000 chassis. Rear-mounted Shelf Interconnect jacks (RJ-14) permit
daisy-chaining of an entire rack of CHP Max5000 chassis for remote monitoring. A terminal
block provides external alarm relay for such functions as an autodialer.
You can identify the chassis by means of one of the following labels on the front right flange
of the chassis: CHP-CHASSIS-19S, CHP-CHASSIS-19S-B, CHP-CHASSIS-19S, or
CHP-CHASSIS-19U.
Table 2.2 lists the mechanical specifications of the chassis..
Tools and Materials
Table 2.3 describes the tools, equipment, and materials that may be required to install,
maintain, and test the chassis. Persons performing the procedures in this manual are
expected to be familiar with the proper and safe use of these tools. Tools or equipment with
equivalent or superior specifications may be substituted for those listed.
Unpacking
All units are tested and inspected before shipment and found to be free of mechanical and
electrical defects. However, upon receiving your product:
1. Examine all shipping containers for any damage due to transit.
2. Unpack all modules and chassis.
Table 2.2 Mechanical Specifications
Characteristic Specification
Dimensions (W x H x
D)
19.0 x 3.5 x 19.625 in (48.3 x 8.9 x 49.8 cm) without front handles
19.0 x 3.5 x 21.25 in (48.3 x 8.9 x 53.4 cm) with front handles
Weight 17 lb (7.7 kg)
Table 2.3 Tools and Materials
Tools/Materials Required
Specifications
Uses
Phillips screwdriver #2 Chassis installation
3/8 inch nutdriver N/A Installing optional CHP-OFFBKT-19 offset mounting kit
ESD grounding
strap
N/A Handling SMM or CMM modules, and application
modules.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals