1-6 CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies 1508685 Rev D
Product Safety
This product conforms to the design safety criteria as detailed in IEC 60950. This criteria
eliminates, or reduces hazards; appropriate labels or markings warn the user of hazards.
Fiber Care and Cleaning
For fiber care information, please reference the ARRIS Fiber Care and Cleaning Guide, P/N
1506507.
FDA CDRH/IEC Laser Classifications
The wavelengths of light typically transmitted through the optical fibers used in hybrid
fiber/coaxial cable (HFC) architecture fall in the infrared band of the light spectrum and are
not visible to the human eye. Transmitters are classified according to their optical power,
wavelength, and aperture size. These classifications are based on Accessible Emission Limit
(AEL), which is determined by the maximum level of laser radiation that the laser can emit
over its full range of capability during operation. Due to the different degree of the AEL, the
laser product can be classified as Class 1, Class 1M, Class 2, Class 2M, Class 3R, Class 3 B, and
Class 4 in increasing order to cause biological damage. Class 2 and 2M wavelengths are
outside the range used for broadband applications and are not discussed further. Refer to
Document Conventions on page 1-4 for laser warnings. Transmitters emit laser radiation, they
are Class 1 or Class 1M according to IEC 60825-01, Amendment 2 and FDA CDRH Laser Notice
50.
ETSI300-386 Electromagnetic compatibility and radio spectrum matters (ERM); telecommunication
network equipment; electromagnetic compatibility (EMC) requirements; product
family standard
Table 1.1 CE Compliance Requirements
Requirement Description
Laser Class AEL (1310nm) AEL (1550nm)
1 (Lowest) <15.6mW
<11.9dBm
<10.0mW
<10.0dBm
1M 15.6 to <52.5mW
11.9 to <17.2dBm
10.0 to <164.0mW
10.0 to <22.15dBm
3R 52.5 to <80.0mW
17.2 to 18.9dBm
Does not exist
1
1. The numerical calculation of Class 3R is less than Class 1M and, therefore, is not defined in this case.
Any power over the maximum limit for Class 1M but less than Class 4 is considered to be Class 3B.
3B 80.0 to <500.0mW
18.9 to <26.99dBm
164.0 to <500.0mW
22.15 to <26.99dBm
4(Highest) 500mW
26.99dBm)
500mW
26.99dBm)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals