There are three different regeneration modes: Automatic, Blocked, and Forced. In the op-
erator panel, in the Settings menu, there is the Engine submenu, where the choice can be
made between blocked or forced regeneration.
There are no requirements for using the function for blocked regeneration of the exhaust
system. This function is available to give the operator the option to block regeneration in
the following cases:
n When the exhaust extractor is installed on the rig during repairs.
n When personnel must be on the upper parts of the rig with the diesel engine running.
n When there is vegetation or other combustible materials in the immediate vicinity of the
exhaust.
!
NOTE: It is not recommended to block regeneration more than necessary. The ma-
chine performs blocked regeneration automatically at the correct exhaust temperature
and when the engine load is normal.
Forced regeneration is only required when the lamp for high soot content in the particulate
filter
comes on.
Symbol Description
High soot content in the particulate filter. The indi-
cator lamp goes off when regeneration is com-
plete.
High exhaust temperature. The indicator lamp
comes on when regeneration has reached high
temperature. The lamp goes off when regenera-
tion is complete.
The indicator lamp flashes when a blocked regen-
eration is being performed.
4.1.7 Stopping Diesel Engine
!
NOTE: Allow the engine to idle a few minutes before turning it off if it is warm.
1.
Make sure mode switch (B) is in position
(3).