Mediant 800C with ZPLS
- 20 -
6.4 Testing the ZPLS Service Module
This section describes the steps for testing proper configuration of the ZPLS Module. For this
purpose, zoom administrators can simulate a failover to verify the service is working as intended.
Network connectivity to Zoom Cloud from the Zoom Node server can be verified via the
Virtual Machine itself. Refer to Section 6.1.3.
To test and validate Local Survivability configuration:
1. In the Navigation menu, click Advanced, then Zoom Node.
2. Click Account Settings.
3. Under Zoom Node, locate Local Survivability.
4. Click the Services tab.
5. Locate the Local Survivability service.
6. Verify the status is Running and there is not any fault information:
7. Click dots at the end of the line and select Diagnose to run diagnostic tests for all services.
8. Check that diagnostic tests for all services are OK. if they are not OK, find the reason and act
according to the procedure in the solution.