6. Lamps and lamp houses
6. LAMPS AND LAMP HOUSES
About this chapter
This chapter enum erates all the supported xenon lamps for the DP2K-12C /11CX and how to replace the xenon lamp in the lamp
house. Also included is the procedure to reset the lamp parameters, which is required after a xenon lamp replacem ent, and the
procedure to realign the lamp in its reflector for optimal performance.
WARNING: DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON LAM P HA NDLING OR SERVICE. ONLY TRAINED AN D Q UALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOW ED TO HAN DLE THE XEN ON LAMP.
CAUTION: Xenon com pact arc lamps are highly pressurized. Wh en ignited, the norm al operating temperature
of the bulb increases the pressu re to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer ’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled . When ever the lamp house, containing a xenon lam p, has to be dismantled or whenever
the protective container or clo th has to be removed from the xenon lamp, authorized protective clothing MUST
be w orn!
WARNING: A lways wear face protection (full face shield) when handling xenon lamp s.
WARNING: Alw ays wear protective clothing (welder’s jacket) when hand ling x enon lamp s.
WARNING: Alwa ys wear clean leather gloves with w rist prote
ctors when handling xenon lamps.
Overview
• Introduction
• Removal of the lamp house
• Removal of the xenon lam p
• Installation of the Xe non lamp
• Installation of the lamp house
• Resetting the lamp parameters
• Realignment of the lamp in its reflector
• Replacement of the Lamp Info module
• Replacement of the UV blocker
• Replacement of the lamp reflector
• Cleaning the Re flec tor of the Lamp House
• Cleaning the UV blocker of the Lamp House
R5905043 DP2K-12C/11CX 19/02/2018