Chapter 9 Ethernet Specification and Operation
9-61
9_
In the New Module dialog box, click the Connection tab to modify the Requested Packet Interval and Input Type
settings. The RPI uses the I/O connection to a Scanner to exchange data at regular intervals, and the units are
micro-seconds. For Input Type select either Unicast or Multicast. The Input Type selections may vary for different
products.
Click OK to create the adapter. The new Delta Adapter appears in the Controller Organizer tree.
9.7.5 Editing Corresponding Addresses for AS300
Refer to section 9.8.5 Assembly Object for defaults of mapping address. Refer to section 9.7.7 on how to open Program
TAG and modify the contents of TAG:C to edit the mapping addresses. Refer to section 9.8.5 Assembly Object for details
on TAG:C.