Protection IP66 and NEMA-4X According to IEC 60529 /
NEMA-250
Shock 150 m/s
2
According to IEC 60068-2-27,
4000 shocks per axis
Vibration 0.15 mm 10 to 58.1 Hz
20 m/s
2
58.1 to 150 Hz
According to IEC 60068-2-6,
floating sinus, 20 cycles, three
axes
Operating altitude <2000 m Above sea level
Allowed degree of pollution 2 Internal. Ensure that no water
or dirt gets into the AMS Asset
Monitor when it is open.
9.7 Environmental conditions – +24 V DC Power
Module
Operating temperature -40 to +70°C
Storage temperature -40 to +85°C
Humidity 5 to 95% Relative humidity without
condensation
Shock 150 m/s
2
According to IEC 60068-2-27,
4000 shocks per axis
Vibration 0.15 mm 10 to 58.1 Hz
20 m/s
2
58.1 to 150 Hz
According to IEC 60068-2-6,
floating sinus, 20 cycles, three
axes
Operating altitude <2000 m Above sea level
Installation Guide Technical data
MHM-97923-PBF March 2024
MHM-97923-PBF, Rev. 2.10 85