Table D-1.
Hazardous zone Categories according to 2014/34/EU Directive
Gas, mists, or vapors Zone 0 1G
Gas, mists, or vapors Zone 1 2G or 1G
Gas, mists, or vapors Zone 2 3G or 2G or 1G
Dust Zone 20 1D
Dust Zone 21 2D or 1D
Dust Zone 22 3D or 2D or 1D
Table D-2. Equipment Protection Level (EPL). EN 60079-14
Explosive Atmosphere Zone EPL
Gas
0 Ga
1 Ga or Gb
2 Ga or Gb or Gc
Dust
20 Da
21 Da or Db
22 Da or Db or Dc
D.3 Applicable Directives, General Standards,
and Norms
Table D-3.
2006/42/EC Machinery directive
2014/30/EU EMC directive
2014/35/EU Low voltage directive
2014/34/EU ATEX directive
EN ISO 12100-1
Safety of machinery - Basic concepts,
general principles for design.
Part 1 - Basic terminology, methodology.
EN ISO 12100-2
Safety of machinery - Basic concepts,
general principles for design.
Part 2 - Technical principles and
specication.
EN 60079-0: 2012/A11:2013 IEC 60079-0: 2011
EN 60079-1: 2014 IEC 60079-1: 2014
EN 60079-7: 2015 IEC 60079-7: 2015
EN 60079-11: 2012 IEC 60079-11: 2011
EN 60079-31: 2014 IEC 60079-31: 2013
EN ISO 80079-36:2016 ISO 80079-36:2016
EN ISO 80079-37:2016 ISO 80079-37:2016

Table of Contents

Other manuals for Emerson Bettis XTE3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis XTE3000 and is the answer not in the manual?

Emerson Bettis XTE3000 Specifications

General IconGeneral
BrandEmerson
ModelBettis XTE3000
CategoryController
LanguageEnglish

Related product manuals