EasyManuals Logo
Home>Fronius>AC Power Distribution>CMT 4000 Advanced

Fronius CMT 4000 Advanced User Manual

Fronius CMT 4000 Advanced
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
CMT welding
General The inputs required for CMT welding are described by reference to the CMT control
panel.
Settings for CMT applications with the CMT remote power source and the RCU 5000i
remote control can be found in the operating instructions for the RCU 5000i remote con-
trol.
CMT welding
1
Press the Process button to select the CMT/CMT pulse process:
2
Press the Material button to select the filler metal and shielding gas used
Filler metals for CMT welding:
1 ER 70 S-3/6 Steel
3 ER 308 CrNi 19 9
5 ER 4043 AlSi 5
6 ER CuSi-A CuSi 3
8 SP 1
1)
10 Steel ER 70 S-3/6
12 CrNi 19 9 ER 308
14 AlSi 5 ER 4043
15 CuSi 3 ER CuSi-A
16 SP 2
1)
To weld the other filler metals, select one of the following processes:
MIG/MAG pulse synergic welding
MIG/MAG standard synergic welding
MIG/MAG standard manual welding
1)
The assignment of SP1 and SP2 depends on the welding database used for the
power source.
3
Press the Wire diameter button to select the diameter of the wire electrode
The assignment of SP depends on the welding database used for the power source.
107
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals