Example
- ALS = 100 %
- Welding voltage currently set: 13 V
- Striking voltage: 13 V + 100 % = 26 V
ALt
Arc length time - Time for increased arc length via ALS. During time ALt there is a con-
tinuous decrease in the arc length to the currently set value.
Unit s
Setting range 0 - 5
Factory setting 0
FAC
Reset power source to factory setting
Press and hold down the Store button for 2 s to restore the factory settings; when
"PrG" appears on the digital display, the power source has been reset
NOTE!
When the power source is reset, all the customised settings in the Setup menu are
lost.
When the power source is reset, jobs are not deleted but are retained in the memory.
The functions in the second level of the Setup menu (2nd) are also not deleted. Excep-
tion: Ignition time-out welding parameter (ito).
2nd
Second level of the Setup menu (see “Setup menu - level 2”)
Parameters for
TIG welding in
the Process
setup menu
2nd
Second level of the Setup menu (see “Setup menu - level 2”)
Parameters for
MMA welding in
the Process
setup menu
NOTE!
If you reset the power source using the Factory parameter FAC, the hot-current
time (Hti) and hot-start current (HCU) parameters are also reset.
Hti
Hot-current time
Unit s
Setting range 0 - 2,0
Factory setting 0,5
HCU
Hot-start current
Unit %
Setting range 0 - 200