Service codes for push-pull calibration
Safety
WARNING!
An electric shock can be fatal.
Before opening the device
â–¶
Turn the mains switch to the "O" position
â–¶
Unplug the device from the mains
â–¶
Ensure the device cannot be switched back on
â–¶
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
Service codes
when the drive
units are disen-
gaged ("open-cir-
cuit" calibration)
Err | Eto
Incorrect measurement during push-pull calibration
Repeat push-pull calibration
Cause:
Remedy:
St1 | E 1
At minimum wire feed speed, the wire-feed unit motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
St1 | E 2
At maximum wire feed speed, the wire-feed motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
St1 | E 3
At minimum wire feed speed, the wire-feed unit motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
St1 | E 4
At minimum wire feed speed, the wire-feed unit motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
St1 | E 5
At maximum wire feed speed, the wire-feed motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
St1 | E 6
At maximum wire feed speed, the wire-feed motor does not deliver any
actual rotational speed value.
Repeat the push-pull calibration. If the error message re-appears: Contact
After-Sales Service.
Cause:
Remedy:
167