Maintenance 271
5 Insert the standard 550 sheet tray into the printer, and push until it stops.
IMPORTANT:
• Do not use excessive force on the tray. Doing so could damage the tray or the inside of the printer.
IMPORTANT:
• After replacing the feed roll and nudger roll, perform two or three test prints.
Resetting the Counter of the Fusing Unit
After replacing the fusing unit, use the operator panel to reset the counter of the fusing unit.
1 Press the (Menu) button.
2 Select Admin Menu, and then press the button.
3 Select Maintenance Mode, and then press the button.
4 Select Reset FusingUnit, and then press the button.
5 Ensure that Are You Sure? appears, and then press the button.