It stands for the percentage of the body part of an acceptable target that goes
across the region. = 100 - S1/ST × 100. S1 stands for the
target body part that goes across the region. ST stands for the
complete target body. The higher the value of is, the more easily the
alarm can be triggered.
Figure 6-7 Set Rule
5.
You can set the parameters of areas by the above steps.
6.
For the arming schedule refer to Set Arming Schedule . For the linkage method
refer to Linkage Method .
7.
Click Save.
6.2.8 Set Object Removal
It detects whether the objects are removed from the region, such as the
exhibits on display. If it occurs, the device can take linkage and the can take measures
to reduce property loss.
Steps
1.
Go to → Event → Smart Event → Object Removal .
2.
Check Enable.
3.
Select a Region. For the region see Draw Area .
4.
Set the rule.
It stands for the percentage of the body part of an acceptable target that leaves
the region.
Network Camera User Manual