INTRODUCTION EXCEL CARE CONTROL ICONS
74-5577–33 (US) 16
EN2B-0184 GE51 R0518 (Europe)
Previous Function name
Folder
Description
IDT
Misc
Copies the input to all outputs.
Controller
Calculate the integral (sum) of the input
signal.
(Excel Web II with OS
3.01.00 or higher only)
Misc
Toggles an output depending to the set, clear
command and clock conditions
Misc
Provides the current value and the value of
the last control cycle.
Comparison
Limits input X to a range between minimum
and maximum.
LINEAR
Legacy XL500
Legacy RACL function: Calculates the linear
product of the inputs.
(Excel Web II with OS
3.01.00 or higher only)
Misc
Converts an input value within definable
limits to an output value
Arithmetic
Calculates the natural logarithm.
Logic
Compares binary values. Returns in output
N(1) the number of TRUE(1) values and in
output N(0) the number of FALSE(0) values.
Max
Comparison
Returns the highest value of all inputs.
Misc
Merges multiple inputs to a combined output.
Result for 4 inputs: Y = X1 + X2*P1 +
X3*P1*P2 + X4*P1*P2*P3
Min
Comparison
Returns the lowest value of all inputs.
Arithmetic
Calculates the remainder of the division A by
B.
Timer
Sets the output to TRUE (1) for the time
defined in the parameter "signal time".
Arithmetic
Multiplies the input values.
Misc
Conditional Switch. Switches the value of a
specified input to the output, depending on
the "Sel X" input.
Misc
X input is copied to the output selected by
the "Sel Y" input. The parameter defines if
the other outputs are left unchanged or set to
0.
Arithmetic
Negates the analog input value
mathematically.
(Excel Web II with OS
3.02.00 or higher only)
Misc
Reads the next scheduled value and the time
until the value changes from the schedule
Energy management
Starts and stops ventilation systems to
precondition rooms when cold outside air is
available during nighttime.
Logic
Negates the binary input value.

Table of Contents

Other manuals for Honeywell EXCEL 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell EXCEL 5000 and is the answer not in the manual?

Honeywell EXCEL 5000 Specifications

General IconGeneral
BrandHoneywell
ModelEXCEL 5000
CategoryControl Systems
LanguageEnglish

Related product manuals