Explains how control icons function, including internal parameters and I/O dialog boxes.
Provides a list of control icons with their names, symbols, and brief descriptions.
Describes the Absolute control icon, its function, and I/O.
Details the Addition/ADD control icon for summing input values.
Explains the ADH2 control icon for legacy RACL heating curve slope calculation.
Describes the Analog Switch/SWI icon for switching analog values based on digital input.
Details the AND control icon for logical AND operations.
Describes the Arcus Cosinus control icon for calculating arcus cosinus function.
Describes the Arcus Sinus control icon for calculating arcus sinus function.
Describes the Arcus Tangens control icon for calculating arcus tangens function.
Explains the Average/AVR control icon for calculating average of analog inputs.
Describes the Cascade/CAS control icon for master and secondary PI control.
Details the Cascade Plus/CAS icon with integral action enable/disable input.
Describes the Changeover Switch/CHA icon for passing analog values based on digital input.
Explains the Compare 2 icon for comparing two analog inputs.
Describes the Comparison icon for comparing two analog inputs.
Describes the Cosinus icon for calculating the cosinus function of X.
Describes the Counter icon for incrementing output based on input changes.
Explains the Cycle/CYC icon for outputting a digital value on a cyclic basis.
Introduces Extended Function Modules (XFMs) for additional control strategy functionality.
Describes the ENHANCED PID icon with advanced PID features.
Details Power Demand Control XFMs for energy consumption management.
Provides a description of the XFM 35 strategy program for load optimization.
Lists general functions provided by the XFM 35 for load optimization.
Details the Sliding Window, Ideal Curve, and Extrapolation algorithms used by XFM 35.
Provides a description of XFM 36-1, 36-1S, and 36-1R single-stage load programs.
Details sequential load switching based on rank within priority groups.
Describes rotational load switching based on ON/OFF duration for XFM 36-1/R.
Explains the HCA icon for adaptable heating compensation curve calculations.
Describes the Mathematical Editor for creating formulas to modify control icon inputs.
Describes the EOH icon for optimizing heating plant start/stop and supply water setpoint.
Explains heating optimization using outdoor air temperature, without a room sensor.
Describes cool-down optimization considering room temperature and sensors.
Describes the EOH3 icon for optimizing heating plant and supply water setpoints.
Explains cool-down optimization based on outdoor air temperature.
Describes the EOV icon for optimizing start/stop of air conditioning systems.
Describes the PID Controller/PID icon for analog output regulation.
Describes the PID Plus Controller/PID icon with an additional digital input.
Describes the ZEB icon for determining setpoints for comfort bands.
Discusses adapting sensor limits and suppressing nuisance alarms.
Switches pump operation between two pumps based on operating hours.
Optimizes start/stop times for air conditioning systems to save energy.
Limits the range of output values sent to a positioning signal.
Adjusts setpoints for Time Programs based on operating modes.
Regulates partial air conditioning systems using ZEB and PID controllers.