7 - 10
If this bar code is read, the next data format, if there is one, will be used on this data. If there
is no other format, the format fails and the raw data is output as 1234AB.
If this bar code is read: the data is output as:
AB1234
<CR>
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn
where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard wedge
interfaces.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied
to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and suffixes are transmitted.
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and
suffixes are not transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not
match your data format requirements generates an error tone and the data in that bar code is not transmitted. If you wish
to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone.
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and
suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you
wish to process this type of bar code without generating an error tone, see Data Format Non-Match Error Tone.
Choose one of the following options. Default = Data Formatter On, Not Required, Keep Prefix/Suffix.
Data Formatter Off
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Formatter On,
Not Required,
Drop Prefix/Suffix

Table of Contents

Other manuals for Honeywell VOYAGER 1202G BF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VOYAGER 1202G BF and is the answer not in the manual?

Honeywell VOYAGER 1202G BF Specifications

General IconGeneral
Product NameHoneywell VOYAGER 1202G BF
CategoryBarcode Reader
Scanner TypeLaser
Battery-Free TechnologyYes
Scan Rate100 scans per second
Decode Capability1D Barcodes
InterfaceUSB, Keyboard Wedge, RS232, IBM 46xx (RS485)
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Weight180g (6.3 oz)
Dimensions180 mm x 66 mm x 92 mm (7.1 in x 2.6 in x 3.6 in)
ConnectivityBluetooth
Radio RangeUp to 10 meters
Scan PatternSingle Line
Humidity5% to 95% relative humidity, non-condensing
Drop SpecificationWithstands 30 drops to concrete from 1.5 m (5 ft)
Power SourceBattery-Free with Supercapacitor
Resolution1D: 4 mil (0.102 mm), 2D: 6.7 mil (0.169mm)