This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Serial Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. The button is activated and deactivated by sending
the following commands:
Activate: SYN T CR
Deactivate: SYN U CR
The scanner scans until a bar code has been read or until the deactivate command is sent. The scanner can also be set to turn
itself off after a specified time has elapsed (see Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s button when using serial commands to trigger the
scanner. Once the scanner has timed out, you can activate the scanner either by pressing the button or using a serial trig-
ger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 30,000 ms.
Read Time-Out

Table of Contents

Other manuals for Honeywell VOYAGER 1202G BF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VOYAGER 1202G BF and is the answer not in the manual?

Honeywell VOYAGER 1202G BF Specifications

General IconGeneral
Product NameHoneywell VOYAGER 1202G BF
CategoryBarcode Reader
Scanner TypeLaser
Battery-Free TechnologyYes
Scan Rate100 scans per second
Decode Capability1D Barcodes
InterfaceUSB, Keyboard Wedge, RS232, IBM 46xx (RS485)
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Weight180g (6.3 oz)
Dimensions180 mm x 66 mm x 92 mm (7.1 in x 2.6 in x 3.6 in)
ConnectivityBluetooth
Radio RangeUp to 10 meters
Scan PatternSingle Line
Humidity5% to 95% relative humidity, non-condensing
Drop SpecificationWithstands 30 drops to concrete from 1.5 m (5 ft)
Power SourceBattery-Free with Supercapacitor
Resolution1D: 4 mil (0.102 mm), 2D: 6.7 mil (0.169mm)