3 - 19
When the scanner goes out of range, 15 attempts are made to link to the base unit. Each attempt consists of approximately
5 seconds of active time followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner
stops trying to connect to the base, but retains any bar codes that may have been saved in batch mode. After one hour, the
scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, no action is taken to relink. When the scanner’s button is pressed, 15 attempts are
made to link to the base. Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle
time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner stops trying to connect to the base, but retains any bar
codes that may have been saved in batch mode. After one hour, the scanner powers off and batch mode data is lost. Refer
to Auto Reconnect Mode, page 3-17, to review other events that can start the relink process.
Reset Scanner and Base
After changing settings, you may need to reset your scanner and base. Scan the Reset Base bar code and wait for the scanner
to unlink and relink to a base. Once that is done, scan the Reset Scanner bar code and wait for the base to unlink and relink to
the scanner.
Reset Scanner
:*:RESET_
Reset Base

Table of Contents

Other manuals for Honeywell VOYAGER 1202G BF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VOYAGER 1202G BF and is the answer not in the manual?

Honeywell VOYAGER 1202G BF Specifications

General IconGeneral
Product NameHoneywell VOYAGER 1202G BF
CategoryBarcode Reader
Scanner TypeLaser
Battery-Free TechnologyYes
Scan Rate100 scans per second
Decode Capability1D Barcodes
InterfaceUSB, Keyboard Wedge, RS232, IBM 46xx (RS485)
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Weight180g (6.3 oz)
Dimensions180 mm x 66 mm x 92 mm (7.1 in x 2.6 in x 3.6 in)
ConnectivityBluetooth
Radio RangeUp to 10 meters
Scan PatternSingle Line
Humidity5% to 95% relative humidity, non-condensing
Drop SpecificationWithstands 30 drops to concrete from 1.5 m (5 ft)
Power SourceBattery-Free with Supercapacitor
Resolution1D: 4 mil (0.102 mm), 2D: 6.7 mil (0.169mm)