UPC-A Redundancy
If you are encountering errors when reading UPC-A bar codes, you may want to adjust the redundancy count. Redundancy
adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the UPC-A
Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back
cover of this manual. Then scan the Save bar code. Default = 0.
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the default setting
(Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.
If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single
scan, it transmits both as one symbology. Otherwise, it transmits the first coupon code it reads.
If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a
single read to transmit the data. No data is output unless both codes are read. Default = Off.
UPC-A Number System 4 Addenda Required
This setting programs the scanner to require a coupon code only on UPC-A bar codes that begin with a “4.” The following
settings can be programmed:
Require Coupon Code: All UPC-A bar codes that begin with a “4” must have a coupon code. The UPC-A bar code with
the coupon code is then transmitted as a single, concatenated bar code. If a coupon code is not found within the Addenda
Timeout period, the UPC-A bar code is discarded.
Don’t Require Coupon Code: If you have selected Require Coupon Code, and you want to disable this feature, scan
Don’t Require Coupon Code. UPC-A bar codes are transmitted, depending on the setting you are using for UPC-A/EAN-
13 with Extended Coupon Code.
Default = Don’t Require Coupon Code.
UPC-A Redundancy
* Off
Allow Concatenation
Require Concatenation
* Don’t Require Coupon Code

Table of Contents

Other manuals for Honeywell VOYAGER 1202G BF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VOYAGER 1202G BF and is the answer not in the manual?

Honeywell VOYAGER 1202G BF Specifications

General IconGeneral
Product NameHoneywell VOYAGER 1202G BF
CategoryBarcode Reader
Scanner TypeLaser
Battery-Free TechnologyYes
Scan Rate100 scans per second
Decode Capability1D Barcodes
InterfaceUSB, Keyboard Wedge, RS232, IBM 46xx (RS485)
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Weight180g (6.3 oz)
Dimensions180 mm x 66 mm x 92 mm (7.1 in x 2.6 in x 3.6 in)
ConnectivityBluetooth
Radio RangeUp to 10 meters
Scan PatternSingle Line
Humidity5% to 95% relative humidity, non-condensing
Drop SpecificationWithstands 30 drops to concrete from 1.5 m (5 ft)
Power SourceBattery-Free with Supercapacitor
Resolution1D: 4 mil (0.102 mm), 2D: 6.7 mil (0.169mm)