EasyManuals Logo
Home>Icom>Transceiver>IC-9100

Icom IC-9100 User Manual

Icom IC-9100
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #158 background imageLoading...
Page #158 background image
149
11
SCANS
A programmed scan searches for signals between
Program Scan Edge channels “1A–3A” and “1b–3b.
Before starting the programmed scan, scan edges
must be programmed into these channels.
See the previous page for scan edge programming.
If the same frequencies are programmed into the
Program Scan Edge channels, the programmed
scan will not start.
q Push [VFO/MEMO] to select the VFO mode.
w Push the mode switch to select the desired operat-
ing mode.
•Theoperatingmodecanalsobechangedwhilescan-
ning.
e Push [TS] one or more times to select a tuning step.
(p. 38)
•Thetuningstepcanalsobechangedwhilescanning.
r
P
ush [MENU] one or more times to display the “M2”
screen (Menu 2).
t
P
ush [SCAN](F-1) to display the “SCAN” screen.
y Set [RF/SQL] open or closed.
•Thescanperformancediffers,dependingonthesquelch
setting when the scan was started. See page 146 for
details.
•Ifthe[RF/SQL]controlfunctionissettoAUTO,”the
squelch is always open in the SSB, CW and RTTY
modes. (pp. 44, 162)
u Hold down [PRO](F-1) for 1 second to select the
desired scan range between “P1, “P2” and “P3.
•Thescansearchesbetweenprogrammedscanchan-
nels 1A–1b (P1), 2A–2b (P2) or 3A–3b (P3).
i Push [PRO](F-1) to start the programmed scan.
•TheMHzandkHzdecimalpoints,andtheselectedscan
range display blink while scanning.
•If
“Up/Down” is selected as
the “MAIN DIAL (SCAN)”
option
in the Scan Set mode, rotating [MAIN DIAL]
changes the scanning direction. (p. 147)
o When the scan detects a signal, the scan stops,
pauses or ignores it, depending on the Scan Re-
sume function, the VSC function or the squelch sta-
tus.
!0 Push [PRO](F-1) to cancel the scan.
Programmed scan/Fine programmed scan (VFO mode)
D About the Fine programmed scan
When a signal is received during Fine programmed
scan, the scanning tuning step is temporarily set to
10 Hz and the scan speed decreases.
q Start the programmed scan.
•Followstepsq through i as described above.
w While scanning, push [FIN](F-3) to switch the scan
function between a programmed scan and a Fine
programmed scan.
e Push [PRO](F-1) to cancel the scan.
[SCAN]/[PRO] [VFO/MEMO] [TS]
[MENU][RF/SQL] Mode switches
PRO
F
SPAN SETFIN
SCAN
PROG SCAN:P2
SCAN MEM SWR TCON VSC
M2
PRO
F
SPAN SETFIN
SCAN
PROG:P1
F
:
±
10k
PRO
F
SPAN SETFIN
SCAN
PROG:P2
F
:
±
10k
Hold down
While Programmed scanning
PRO
F
SPAN SETFIN
SCAN
PROG SCAN:P2
PRO
F
SPAN SETFIN
SCAN
F−PROG SCAN:P2
While Fine programmed scanning
Push
Push
Push

Table of Contents

Other manuals for Icom IC-9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-9100 and is the answer not in the manual?

Icom IC-9100 Specifications

General IconGeneral
BrandIcom
ModelIC-9100
CategoryTransceiver
LanguageEnglish

Related product manuals