152
11
SCANS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
F (Delta Frequency) scan searches for signals within
the specified range with the displayed VFO frequency
or Memory channel frequency as the center frequency.
The frequency range is specified by the width of the
selected span.
q Push [VFO/MEMO] once or twice to select the VFO
mode or memory mode.
w
P
ush [MENU] one or more times to display the “M2”
screen (Menu 2).
e
P
ush [SCAN](F-1) to display the “SCAN” screen.
r Set [RF/SQL] open or closed.
•Thescanperformancediffers,dependingonthesquelch
setting when the scan was started. See page 146 for
details.
•Ifthe[RF/SQL]controlfunctionissettoAUTO,”the
squelch is always open in the SSB, CW and RTTY
modes. (pp. 44, 162)
t Push [SPAN](F-4) one or more times to select the
desired F span width.
•±5 kHz, ±10 kHz, ±20 kHz, ±50 kHz, ±100 kHz,
±500 kHz and ±1 MHz are selectable.
y Set the center frequency of the F scan.
•In theVFO mode,push thekeypad or rotate [MAIN
DIAL] to set the center frequency.
•Inthememorymode,rotate[M-CH]toselectthede-
sired Memory channel whose frequency will be the cen-
ter frequency.
u Push [F](F-2) to start the F scan.
•F SCAN, the MHz and kHz decimal points blink while
scanning.
•If
“Up/Down” is selected as
the “MAIN DIAL (SCAN)”
option
in the Scan Set mode, rotating [MAIN DIAL]
changes the scanning direction. (p. 147)
i When the scan detects a signal, the scan stops,
pauses or ignores it, depending on the Scan Re-
sume function, VSC function or the squelch status.
o Push [F](F-2) again to cancel the F scan.
F scan and Fine F scan
D About the Fine F scan
When a signal is received during Fine F scan, the
scanning tuning step is temporarily set to 10 Hz and
the scan speed decreases.
q Start F scan.
•Followstepsq through u as described above.
w While scanning, push [FIN](F-3) to switch the scan
function between F scan and Fine F scan.
e Push [F](F-2) to cancel the scan.
[SCAN] [VFO/MEMO] [M-CH]
[MENU]
[F] [SPAN]
[MAIN DIAL]
SCAN MEM SWR TCON VSC
M2
MEM
F
SPAN SETSEL
SCAN
F
:
±
10k
MEM
F
SPAN SETFIN
SCAN
F
SCAN
±
20k
MEM
F
SPAN SETSEL
SCAN
F
:
±
20k
F
While F scanning
Keypad
MEM
F
SPAN SETFIN
SCAN
MEM
F
SPAN SETFIN
SCAN
F−
F
SCAN
F
SCAN
±
20k
±
20k
While Fine F scanning
Push
Push
Push
Push

Table of Contents

Other manuals for Icom IC-9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-9100 and is the answer not in the manual?

Icom IC-9100 Specifications

General IconGeneral
BrandIcom
ModelIC-9100
CategoryTransceiver
LanguageEnglish

Related product manuals