7
OTHER FUNCTIONS
7-35
CI-V information
D Command table (Continued)
Remarks:
*
1
When sending the power ON command (18 01), you need to repeatedly send “FE” for
13 milliseconds before the standard format. The following is the approximate number
of needed repetitions. (Not necessary when the IC-R30 is connected through the
[USB] connector.)
19200 bps: 27 “FE”s
9600 bps: 13 “FE”s
4800 bps: 7 “FE”s
×7
Example: When using 4800 bps
F C9EFEF E E 10810 DF
Preamble IC-R30’s
address
Controller’s
address
Command
Sub
command
Post
amble
*
2
When you turn OFF the receiver, the data output setting is automatically set to OFF.