7
OTHER FUNCTIONS
7-31
■ CI-V information (Continued)
D Data format
The CI-V system can be operated using the following data formats. Data formats differ,
depending on the command numbers. A data area or sub command is added to some
commands.
FE FE 9C E0 Cn Sc Data area FD
Preamble
code (fixed)
Receiver’s
default address
Controller’s
default address
Command number
(see the command table)
Sub command number
(see the command table)
BCD code data such as
for frequency, memory
number entry
(see the data content description)
End of message
code
(fixed)
oller
qwerty u
FE FE E0 9C Cn Sc Data area FD
qwer* ty u
*The reply message from the receiv
er is command “FB” (OK) or “FA” (NG).