Parameter Description MD320/MD320N User Manual
146
FB-01
Swing frequency amplitude Factory default value 0.0%
Setup range 0.0% to 100.0%
FB-02
Kick frequency amplitude 1 Factory default value 0.0%
Setup range 0.0% to 50.0%
This parameter is used to determine the values of swing amplitude and kick frequency. The
swing frequency is limited by the frequency upper limit and frequency lower limit.
The swing amplitude is relative to the central frequency (variable swing amplitude, select
FB-00=0): swing amplitude AW=frequency source F0-07 times swing amplitude FB-01.
The swing amplitude is relative to the maximum frequency (fixed swing amplitude, select
FB-00=1): swing amplitude AW=maximum frequency F0-12 times swing amplitude FB-01.
Kick frequency=swing amplitude AW times kick frequency amplitude FB-02. That is the value of
kick frequency relative to the swing amplitude when the swing frequency is running.
If the swing amplitude relative to the central frequency (variable swing amplitude, select
FB-00=0) is selected, the kick frequency is a variable value.
If the swing amplitude relative to the maximum frequency (fixed swing amplitude, select
FB-00=1) is selected, the kick frequency is a xed value.
FB-03
Swing frequency cycle Factory default value 10.0s
Setup range 0.0s ~ 3000.0s
Swing frequency cycle: It refers to the time of a complete cycle of swing frequency.
FB-04 Time constant of triangular wave boost is relative to FB-03 swing frequency cycle.
Triangular wave boost time =swing frequency cycle FB-03 × time constant of triangular wave
boost FB-04 (unit: s)
Triangular wave falling time =swing frequency cycle FB-03 × (1-time constant of triangular wave
boost FB-04 (unit: s)
FB-04
Time constant of triangular
wave boost
Factory default value 50.0%
Setup range 0.0% ~ 100.0%
FB-05
Setup length Factory default value 1000m
Setup range 0m~65535m
FB-06
Actual length Factory default value 0m
Setup range 0m~ 65535m
FB-07
Number of pulses each
meter
Factory default value 100.0
Setup range 0.1~ 6553.5