b. Insert the lock into the security slot on the switch and set the lock to the locked posion using
the key. See Figure 55 on page 113.
Figure 55: Securing the EX2300-C Switch by Using the Security Slot
Mounng an EX2300 Switch on Two Posts of a Rack or Cabinet
Before mounng the switch on two posts of a two-post or a four-post rack:
• Verify that the site meets the requirements described in "Site Preparaon Checklist for EX2300
Switches" on page 53.
• Place the rack in its permanent locaon, allowing adequate clearance for airow and maintenance,
and secure it to the building structure.
• Read
General Safety Guidelines and Warnings
, with parcular aenon to
Chassis and Component
Liing Guidelines
.
Ensure that you have the following parts and tools available:
• Phillips (+) screwdriver, number 2
• 2 mounng brackets and 8 mounng screws (provided with EX2300 switches except the EX2300-C
switch model and separately orderable for EX2300-C switches)
• Screws to secure the chassis to the rack (not provided)
• 2-in.-recess front-mounng brackets from the separately orderable four-post rack-mount kit if you
will mount the switch in a recessed posion (not applicable for EX2300-C switches)
You can mount all EX2300 switches on two posts of a two-post or a four-post 19-in. rack or cabinet by
using the mounng brackets and screws provided with EX2300 switches except the EX2300-C switch
113