• The administrave status on each port by issuing the command show interfaces terse.
• The PoE status on each port by issuing the command show poe interface.
EX2300 Cooling System
IN THIS SECTION
Airow Direcon in EX2300 Switches with 24 Ports with PoE Capability Except the EX2300-24MP Switch
Model | 41
Airow Direcon in EX2300-24MP Switch Model | 42
Airow Direcon in EX2300 Switches with 48 Ports with PoE Capability Except the EX2300-48MP Switch
Model | 43
Airow Direcon in EX2300-48MP Switch Model | 44
Airow Direcon in EX2300 Switches without PoE Capability | 45
The cooling system in EX2300 switches—except EX2300-C which is the compact, fanless model,
EX2300-24MP, and EX2300-48MP models—consists of two fans built-in along the rear of the chassis
that provide front-to-back chassis cooling.
The cooling system in EX2300-C switches consists of the vents on the top of the chassis and the
heatsinks installed in the rear panel in PoE models. Do not block the vents on the chassis; doing so can
lead to overheang of the switch chassis.
The cooling system in EX2300-24MP switches consists of three fans built in along the right side panel of
the chassis that provide side-to-side chassis cooling. The cooling system in EX2300-48MP switches
consists of four fans built in along the right side panel of the chassis that provide side-to-side chassis
cooling.
40