MAINTENANCE
SERVICE PROCEDURE
LUBRICATE IDLER ADJUSTMENT ROD
(left and right: 1 place each)
1.
Remove bolt (2), then remove cover (1).
2. Pump in grease through the grease fitting marked by the arrow.
CHECK FOR LOOSE ROPS MOUNT BOLTS
(If equipped)
Check for loose and damaged bolts.
If a loose bolt is found, tighten it to a torque of 927 ± 103 N·m (94.5 ± 10.5 kgf·m, 684 ± 76 lbft)
If a damaged bolt is found, replace the bolt with a genuine Komatsu bolt.
4 - 66