8: Setup Mode: Channel Configuration
UDS2100 Device Server User Guide 53
Table 8-7. Modem Mode Messages
Command was executed without error.
A network connection has been established.
A network connection has been closed.
RING n.n.n.n.
A remote device, having IP address n.n.n.n, is connecting to this
device.
Received commands must begin with the two-character sequence AT and be
terminated with a carriage return character.
The unit ignores any character sequence received not starting with AT, and only
recognizes and processes single AT-style commands. The unit treats compound
AT commands as unrecognized commands.
If the Full Verbose option is in effect, the unit responds to an unrecognized
command string that is otherwise formatted correctly (begins with AT and ends
with carriage return) with the "OK" message and takes no further action.
If the Numeric Response option is in effect, the unit responds to an
unrecognized command string that is otherwise formatted correctly with a "0"
message and takes no further action.
When an active connection is in effect, the unit transfers data and does not
process commands received from the serial interface.
When a connection is terminated or lost, the unit reverts to command mode.
When an active connection is in effect, the unit terminates the connection if it
receives the following sequence from the attached serial device:
No serial data is received for one second.
The character sequence +++ is received, with no more than one second
between each two characters.
No serial data is received for one second after the last + character. At this
time, the unit responds affirmatively per the selected echo/response mode.