EasyManuals Logo
Home>Lantronix>Server>UDS2100

Lantronix UDS2100 User Manual

Lantronix UDS2100
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
A: Troubleshooting and Contact Information
UDS2100 Device Server User Guide 74
Problems and Error Messages
Table A-2. Problems and Error Messages
Problem/Message
Reason
Solution
When you issue the ARP –S
command in Windows, the "ARP
entry addition failed: 5" message
displays.
Your currently logged-in user
does not have the correct
rights to use this command
on this PC.
Have someone from your IT
department log you in with
sufficient rights.
When you attempt to assign an IP
address to the unit by the ARP
method, the "Press Enter to go
into Setup Mode" error "(described
below) message displays. Now
when you Telnet to the device
server, the connection fails.
When you Telnet to port 1
on the device server, you
are only assigning a
temporary IP address. When
you Telnet into port 9999
and do not press Enter
quickly, the device server
reboots, causing it to lose
the IP address.
Telnet back to Port 1. Wait for it to
fail, then Telnet to port 9999 again.
Make sure you press Enter quickly.
When you Telnet to port 9999, the
"Press Enter to go into Setup
Mode" message displays.
However, nothing happens when
you press Enter, or your
connection is closed.
You did not press Enter
quickly enough. You only
have 5 seconds to press
Enter before the connection
is closed.
Telnet to port 9999 again, but press
Enter as soon as you see the
"Press Enter to go into Setup
Mode" message.
When you Telnet to port 1 to
assign an IP address to the device
server, the Telnet window does not
respond for a long time.
You may have entered the
Ethernet address incorrectly
with the ARP command.
Confirm that the Ethernet address
that you entered with the ARP
command is correct. The Ethernet
address may only include numbers
0-9 and letters A-F. In Windows
and usually in Unix, the segments
of the Ethernet address are
separated by dashes. In some
forms of Unix, the Ethernet address
is segmented with colons.
The IP address you are
trying to assign is not on
your logical subnet.
Confirm that your PC has an IP
address and that it is in the same
logical subnet that you are trying to
assign to the device server.
The device server may not
be plugged into the network
properly.
Make sure that the Link LED is lit. If
the Link LED is not lit, then the
device server is not properly
plugged into the network.
When you try to assign an IP with
DeviceInstaller, you get the
following :
"No response from device!
Verify the IP, Hardware
Address and Network Class.
Please try again."
The cause is most likely one
of the following:
The hardware address you
specified is incorrect.
The IP address you are
trying to assign is not a valid
IP for your logical subnet.
You did not choose the
correct subnet mask.
Double-check the parameters that
you specified.
Note: You cannot assign an IP
address to a device server through
a router.

Table of Contents

Other manuals for Lantronix UDS2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix UDS2100 and is the answer not in the manual?

Lantronix UDS2100 Specifications

General IconGeneral
Isolation1.5 kV
CertificationFCC, C/UL, CSA, VCCI, CE, TUV, CTick
Serial interface typeRS-232/422/485
Serial ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Electrostatic Discharge (ESD) protection15 kV
USB 2.0 ports quantity0
Supported network protocolsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, RFC2217
Built-in processorLantronix DSTNI-EX
Processor frequency48 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP
Flash memory2 MB
RAM capacity0.256 MB
LED indicatorsLAN, Y
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)10 - 90 %
Input voltage9 - 30 V
Weight and Dimensions IconWeight and Dimensions
Weight400 g
Dimensions (WxDxH)72 x 23 x 95 mm

Related product manuals