Rated data at 400/500 V mains voltage
3−7
L
EDB82MV752 EN 5.2
3.3 Rated data at a mains voltage of 400/500 V
3.3.1 Operation with rated power (normal operation)
Typical motor power
Three−phase asynchronous motor
(4−pole)
P
N
[kW] 0.55 0.75 1.5 2.2
P
N
[hp] 0.75 1.0 2.0 3.0
8200 motec Type E82MV551_4B E82MV751_4B E82MV152_4B E82MV222_4B
Mains voltage U
mains
[V] 3/PE AC 320 V − 0 % ... 550 V + 0 % ; 45 Hz − 0 % ... 65Hz + 0 %
Data for operation on 3/PE AC 400 V 500 V 400 V 500 V 400 V 500 V 400 V 500 V
Rated mains current I
mains
[A] 1.8 1.4 2.4 1.9 3.8 3.0 5.5 4.5
Rated output current at
switching frequency
2 kHz
I
N24
[A]
2)
2.1 1.8 2.9 2.4 4.6 3.9 6.7 5.6
4 kHz
8 kHz I
N8
[A] 1.8 1.6 2.4 2.1 3.9 3.5 5.6 5.0
16 kHz I
N16
[A] 1.2 1.1 1.6 1.4 2.5 2.3 3.6 3.2
Max. permissible output
current for 60 s at
switching frequency
1)
2 kHz
I
max24
[A] 2.7 2.4 3.6 3.2 5.8 5.2 8.4 7.6
4 kHz
8 kHz I
max8
[A] 2.7 2.4 3.6 3.2 5.8 5.2 8.4 7.6
16 kHz I
max16
[A] 1.8 1.6 2.4 2.1 3.9 3.5 5.3 4.8
Output voltage U
M
[V] 3~ 0 ... U
mains
/ 0 ... 650 Hz
Power loss (operation with I
N8
) P
v
[W] 35 45 70 95
Dimensions L x W x H [mm] 202 x 156 x 151 230 x 176 x 167
Weight m [kg] 2.8 2.8 4.1 4.1
Typical motor power
Three−phase asynchronous motor
(4−pole)
P
N
[kW] 3.0 4.0 5.5 7.5
P
N
[hp] 4.1 5.4 7.5 10.2
8200 motec Type E82MV302_4B E82MV402_4B E82MV552_4B E82MV752_4B
Mains voltage U
mains
[V] 3/PE AC 320 V − 0 % ... 550 V + 0 % ; 45 Hz − 0 % ... 65Hz + 0 %
Data for operation on 3/PE AC 400 V 500 V 400 V 500 V 400 V 500 V 400 V 500 V
Rated mains current I
mains
[A] 9.5 7.6 12.3 9.8 16.8 13.4 21.5 17.2
Rated output current at
switching frequency
2 kHz
I
N24
[A]
2)
8.8 7.0 11.4 9.2 15.6 12.5 16.5 13.2
4 kHz
8 kHz I
N8
[A] 7.3 5.8 9.5 7.6 13.0 10.4 16.5 13.2
16 kHz I
N16
[A] 4.7 4.2 6.1 5.5 8.4 7.6 10.7 9.6
Max. permissible output
current for 60 s at
switching frequency
1)
2 kHz
I
max24
[A] 11.0 8.7 14.2 11.4 19.5 15.6 24.8 19.8
4 kHz
8 kHz I
max8
[A] 11.0 8.7 14.2 11.4 19.5 15.6 24.8 19.8
16 kHz I
max16
[A] 7.1 6.4 9.1 8.2 12.7 11.4 16.1 14.5
Output voltage U
M
[V] 3~ 0 ... U
mains
/ 0 ... 650 Hz
Power loss (operation with I
N8
) P
v
[W] 14o 180 230 290
Dimensions L x W x H [mm] 325 x 211 x 163 (223**)
Weight m [kg] 9.7 9.7 9.7 9.7
Bold print = data for operation at a switching frequency of 8 kHz (Lenze setting)
1)
Currents for periodic load change: 1 min overcurrent time with I
max
and 2 min base load time with 75 % I
Nx
2)
Under different operating conditions possible for some types: Operation with increases rated output current with the same load change
cycle ( 3−9)
** for wall mounting or with a supplementary module (E82ZMV)