80 user attendance error messages
Error code Description Action
80.01 The maintenance kit is nearly low. The backup
roll or fuser page count threshold has been
reached.
See
“Maintenance kit service check” on
page 159.
80.09 The maintenance kit is nearly low. The
user‑selected EWS set point has been reached.
80.11 The maintenance kit is low. The backup roll or
fuser page count threshold has been reached.
80.19 The maintenance kit is low. The user‑selected
EWS set point has been reached.
80.21 The maintenance kit is very low. The backup roll
or fuser page count threshold has been reached.
80.29 The maintenance kit is very low. The
user‑selected EWS set point has been reached.
80.31 Replace the maintenance kit. The backup roll or
fuser page count threshold has been reached.
The fuser may continue to function beyond end
of life.
80.39 Replace the maintenance kit. The user‑selected
EWS set point has been reached. The fuser may
continue to function beyond end of life.
82 user attendance error messages
Error code Description Action
82.11 The waste toner bottle is nearly full. The sensor
threshold has been reached.
See
“Waste toner bottle service check” on
page 158.
82.19 The waste toner bottle is nearly full. The user-
selected EWS set point has been reached.
82.31 Replace the waste toner bottle. The sensor end
of life threshold has been reached.
83 user attendance error messages
Error code Description Action
83.01 The transfer module is nearly low. The transfer
module page count threshold has been reached.
83.09 The transfer module is nearly low. The
user‑selected EWS set point has been reached.
83.11 The transfer module is low. The transfer module
page count threshold has been reached.
5028
Diagnostic information
152