 MMX8x4-HT series – User's Manual 139


Command and Response
ç <loc>.ServerPort(<port_no>)
æ <loc>.ServerPort(<port_no>)
Example
ç 
æ 
Connecting to a TCP Server
Command and Response
ç <loc>:connect()
æ <loc>:connect
Example
ç 
æ 
Disconnecting from a TCP Server
Command and Response
ç <loc>:disconnect()
æ <loc>:disconnect
Example
ç 
æ 
Setting the Delimiter Hex
  
Space). The value has to be in hex format (e.g.0D, 0A, 20).
Command and Response
ç <loc><delimiter>
æ <loc><delimiter>
Parameters
The <delimiter> parameter can be max. 8-character long (16 hex digit) in hex format.
Example
ç 
æ 
...00PWR_0100...
Delimiter Delimiter
Stored string
Setting the Timeout

saves the data into the Rx, RxHex, Hash properties. The timeout setting is useful if there is no special or easily

Command and Response
ç <loc><timeout>
æ <loc><timeout>
Parameters
The <timeout> parameter sets the time value in milliseconds: 0 means the timeout is disabled, min. value
is 10.
Example
ç 
æ 


the clear() method is called.
TIPS AND TRICKS: 
follow each other, the action will execute once. (A Condition can be detected in Event Manager if a change
happens. But if the same string is saved into the property after each other, it will not cause a change.)
Command and Response
ç <loc>.Rx
æ <loc>

Parameters
The  parameter can be max. 128 byte long.
Example
ç 
æ 

Table of Contents

Other manuals for Lightware MMX8x4-HT400MC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware MMX8x4-HT400MC and is the answer not in the manual?

Lightware MMX8x4-HT400MC Specifications

General IconGeneral
BrandLightware
ModelMMX8x4-HT400MC
CategoryMatrix Switcher
LanguageEnglish

Related product manuals