3.2 About the Control Panel
51
3.2 About the Control Panel
With the optional control panel (FR-PA02
-02
), you can run the inverter, set the
frequency, monitor the operation command display, set parameters, and display an
error.
3.2.1 Names and functions of the control panel (FR-PA02
-02
)
Hz
A
PU
RUN
MON
EXT
Display
LED 4 digits
Mode key
MODE SET REV
STOP
RESET
FWD
Setting key
STOP
RESET
RUN
Hz
A
PU
RUN
MON
EXT
STOP/RESET ke
RUN key
Cover opened
Unit indication
Operation status
indication
STOP/RESET ke
Up/down ke
sForward ke
Reverse key
"
""
"
Key indication
Key Description
RUN
key
Used to give a start rotation command.
MODE
key
You can select the operation mode or setting mode.
SET
key
You can determine the frequency and parameter setting.
/
key
"
Used to increase or decrease the running frequency
consecutively. Hold down this key to change the frequency.
"
Press this key in the setting mode to change the parameter
setting consecutively.
FWD
key
Used to give a forward rotation command.
REV
key
Used to give a reverse rotation command.
STOP
RESET
key
"
Used to stop operation.
"
Used to reset the inverter when its output is stopped by the
activated protective function.
"
""
"
Unit indications, operating status indications
Indication Description
Hz Lit to indicate the frequency.
A Lit to indicate the current.
RUN
Lit while the inverter is operating. Lit to indicate forward rotation, and flickers to
indicate reverse rotation.
MON Lit in the monitor display mode.
PU Lit in the PU operation mode.
EXT Lit in the external operation mode.
3