© MOOG 2019
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
2-5-7. OTHER
2.5.7.1. RESET COMMAND
2.5.7.2. SET RTC
2.5.7.3. GET RTC
2-5-8. ERROR CODE
2-5-9. ADC/DAC CHANNEL
Core position voltage(DCDT)
Accumulator position voltage
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
R T 0 0 y y / m m / d d h h : m m : s s
Set RTC.
0 1 2 3 It is reflected at the time of transmission.
R T
Error of time format error becomes "data value range error".
0 1 2 3
R T 0 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
R T y y / m m / d d h h
:
m m
:
s s
Number and Data part of ※ 1
↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑
| | | | | |
Data: write value, read value
| |
Number: other than command and data (address, file number, command extension number)
Command: the first two characters
Corresponding command code does not exist
Define area of command string
Number specification error
Value other than specified value for number specification
Data value is outside the specified range
The command is not in the specified format
Number specification or data value is not a correct numeric string (hexadecimal / decimal)
Accessed an unregistered file
Failed to write to Flash memory