MTS 793 Controller Hardware
FlexTest IIm Controller Connections
174
HSM Connections
The outputs provide 24 V DC to turn on the HSM solenoids.
Cable specification • P28 is a 4-contact CPC male connector (AMP Incorporated).
• Cable–18 AWG/2 connector type SJOOW-A for on/off HSMs 18
AWG/3 connector type SJOOW-A for high/low HSMs
• Cable assembly numbers:
– 290.XX HSM, on/off, 24 V DC, PN 039-705-3XX 18/2 SJO
– 290.XX/294.XX HSM, high/low, 24 V DC, PN 039-705-5XX 18/
3 SJO
– 298.11 HSM, on/off, 24 V DC, PN 039-708-1XX 18/2 SJO
1
2
4
Low Pressur
DC Common
High Pressur
To HSM
Solenoids
J28From
Hydraulic I/O
Connector J28 controls the
low-pressure and high-
pressure solenoids of a
hydraulic service manifold.